Abstract
Heat transfer factors and thermal efficiency are calculated for a heat pipe absorber array connected to a common manifold. Arrays with less than ten heat pipes are shown to have significantly less efficiency than a conventional flow-through collector. Efficiency is also sensitive to the heat transfer rate per unit temperature difference from the heat pipe fluid to the manifold fluid divided by that from the heat pipe surface to the ambient, with maximum efficiency occurring for ratios greater than 100.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.