Abstract
The steady-state laminar and incompressible vapor flow in four partially-heated concentric annular heat pipe (CAHP) is studied. The governing equations are solved numerically, using finite volume approach based on collocated grids. The first order upwind scheme and the QUICK scheme are used in the numerical solution. The vapor pressure distributions and velocity profiles along the annular vapor space are predicted for a number of test cases in the range of low to moderate radial Reynolds numbers. The results show that in a partially-heated annular heat pipe, as the radial Reynolds number increases, a number of recirculation zones may be created at both ends of the evaporator and condenser sections. The size and location of the recirculation zones are predicted and their effects on the performance of an annular heat pipe are discussed qualitatively.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Computational Engineering Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.