Abstract

Three heat pipes with nanofluids of Al2O3-water, CuO-water and SiO2-water were tested experimentally. The temperature distribution of their start-up process was analysed, and compared the heat pipe with water. The results showed that the start-up way of heat pipe filled with nanofluids was coincident, the heat pipe filled with nanofluids showed a lower start-up temperature and a shorter start-up time in evaporator section compared with heat pipe filled with water, the temperature drop between evaporator section and condenser section for the heat pipe filled with nanofluids were reduced by 2-5°C than that of the heat pipe filled with water. The effect of the length of the heating section of heat pipe filled with nanofluids on the start-up process was little.

Full Text
Published version (Free)