Abstract

Hollow fiber membranes have been widely employed for water and wastewater treatments. Nevertheless, understanding the filtration characteristics of hollow fiber membranes is complicated by the axial distributions of transmembrane pressure (TMP) and flux, which are key factors for both fouling control and module design. In this study, model equations to account for different fouling mechanisms were derived to analyze the performance of submerged hollow fiber systems with different conditions in terms of feed water characteristics and membrane material. A series of experiments with synthetic feed and raw water were carried out using hydrophilic and hydrophobic membrane modules. The model successfully fits the experimental results for synthetic feed as well as raw water. The major fouling mechanisms for filtration of raw water using hydrophilic and hydrophobic membranes are identified as cake formation and standard blocking, respectively. The model calculations indicate that the distributions of flux and cake (fouling) resistance are sensitive to the fiber length of the membrane.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.