Abstract

One of the promising ways to reduce operating losses in main gas pipelines is pre-cooling of compressed gas using heat-using absorption water-ammonia refrigeration machines (AWRM), which utilize the waste heat of the exhaust products of the combustion of gas pumping units. The object of research is the energy characteristics of the AWRM in a wide range of operating parameters (outdoor temperatures), which are currently not studied. A methodology for modeling AWRM modes is developed, analytical studies are conducted and the results are obtained in a wide range of outdoor temperatures. The study is conducted using theoretical analysis of AWRM cycles in a wide range of outdoor temperatures and temperatures of the cooling object. The analysis of the calculation results showed that in the range of design parameters there is a maximum energy efficiency AWRM. The most obvious is the presence of a maximum for operating conditions at cooling medium temperatures of 20…32 °С and low temperatures of the cooling object (minus 25 °С). As the temperature of the cooling object decreases, the maximum energy efficiency shifts to the region of high temperatures of the heating medium, and its numerical values decrease. At heating source temperatures from 90 °С to 130 °С, the electric power of the circulation pump has a maximum value. Subsequently, with an increase in the temperature of the heating source, its asymptotic decrease and slow decrease are observed. In this case, the greatest changes occur at elevated temperatures of the cooling medium (32 °С). The simulation results allow to determine the most energy-efficient operating modes of the AWRM with various sources of thermal energy (temperatures from 90 to 160 °С) and to develop cooling systems for a wide temperature range (minus 30…15 °С). To achieve such optimal conditions, an appropriate combination of the composition of the working fluid and the temperature of the heating source is necessary.

Highlights

  • The gas transportation system of Ukraine is designed to supply gas to both domestic consumers and fuel transit to Western Europe

  • The situation with the replacement of existing equipment with modern equipment is associated with significant investments, on the one hand, and the uncertainty with the transit of Russian natural gas through Ukrainian gas transmission systems in the near future [3, 4]

  • An analysis of ways to increase the energy efficiency of gas compressor units [5] shows that one of the prom­ ising areas could be pre-cooling of the compressed gas using heat-using absorption water-ammonia refrigeration machines (AWRM) that utilize the waste heat of the exhaust products of combustion [6, 7]

Read more

Summary

Introduction

An analysis of ways to increase the energy efficiency of gas compressor units [5] shows that one of the prom­ ising areas could be pre-cooling of the compressed gas using heat-using absorption water-ammonia refrigeration machines (AWRM) that utilize the waste heat of the exhaust products of combustion [6, 7] It is shown [5] that for the current economic situation (July 2019) in the Ukrainian gas market, the daily decrease in operating costs in typical gas pipelines with a decrease in gas temperature before compression by 20 K in gas compressor units ranges from 1800 to 3360 USD

Objectives
Methods
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.