Abstract

We describe a high-performance liquid chromatographic method with electrochemical detection for quantifying pyronaridine in rhesus monkey (Macaca mulata) blood and urine samples. The detection limit is 20 ng/ml at a signal-to-noise ratio of 4 in 0.5-ml samples of blood or urine. Blood analysis includes a liquid-liquid extraction and a subsequent solid-phase extraction that removes an interferent present in blood. For urine, a back-extraction is substituted for the solid-phase extraction step. The method uses an analogue of amodiaquine as internal standard, a 10-microns rigid macroporous styrene-divinylbenzene copolymer column and a mobile phase of 1% (v/v) triethylamine in methanol-water (34:66, v/v). The method was applied to samples of blood and urine from a monkey after a single intramuscular dose of pyronaridine tetraphosphate (160 mg as base).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.