Abstract

Actuator rate limit deteriorates control performance, and may even lead to system instability in precision process control. In this paper, a first-order plus time-delay (FOPTD) system class with actuator rate limit is considered. The describing function (DF) of the rate limiter is derived to obtain the describing functions of the closed-loop and open-loop systems, and the onset frequency in the Nichols chart is used to analyze the rate limit effects in frequency domain. A fractional-order proportional-integral (FOPI) controller is first designed based on the flat phase constraint, crossover frequency, and phase margin specifications. Then a traditional integer-order PID (IOPID) controller is designed based on the same specifications to compare with the FOPI controller in the presence of actuator rate saturation. A careful simulation study is presented to validate all the conclusions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.