Abstract
In ITER two heating (HNBI) and one diagnostic neutral beam injectors (DNBI) are foreseen. Inside these components there are very stringent limits on the magnetic field (the flux density must be below some G along the ion path and below 20 G in the neutralizing regions). To achieve these performances in an environment with high stray field due to the plasma and the poloidal field coils (PFC), both passive and active shielding systems have been foreseen. The present design of the magnetic field reduction systems (MFRS) is made of seven active coils and of a box surrounding the NBI region, consisting of ferromagnetic plates. The electromagnetic analyses of the effectiveness of these shields have been performed by a 3D FEM model using ANSYS code for the HNBI. The ANSYS models of the ferromagnetic box and of the active coils are fully parametric, thus any size change of the ferromagnetic box and coils (linear dimension or thickness) preserving the overall box shape could be easily reproduced by simply changing some parameter in the model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.