Abstract
Saturation is a condition in which the magnets are fully transformer cores and generate maximum magnetic flux. Some parts affect the resilience and create distortions that can harm the heart. Core saturation can also increase the temperature and magnetization current transformer. In this study, we proposed a measurement method to obtain the necessary parameters to calculate a reliable indicator of the state of the transformer core saturation. The main effects of nonlinear flow in the transformer core are saturation, eddy current and hysteresis. In saturation, the core transformer is as a source of generating harmonic currents, some of which will flow directly to the primary and secondary windings. The method is based on the magnetization current, the phenomenon of harmonics and power factor is evaluated by measuring the no-load current at three-phase transformer, with a high magnetic flux density imposed. Measurements were taken at each phase of the transformer core. The transformer is connected to a variable voltage variable frequency (VVVF) as a voltage source and the investigation carried out at various flux densities. The results showed that the magnetization current and harmonic phenomena increased significantly when the high magnetic flux density and vice versa injected with power factor declined sharply. This phenomenon can be used as an indication of saturation of the 3-phase transformer core.
Highlights
Construction of three-phase transformer is basically a single-phase transformer that is arranged into three pieces in the iron core
The relationship between the magnetization current and total harmonic current distortion (THDi) of the magnetic flux density at a frequency of 50 Hz is shown in Figure 3 and Figure 4
THDi increases when the transformer that is charged with a magnetic flux density is higher
Summary
Construction of three-phase transformer is basically a single-phase transformer that is arranged into three pieces in the iron core. A transformer consists of a coil and an iron core. By the standards of IEC (International Electro technical Commissioning) 1000.4 - 11, they’re classified into harmonic interference waveform distortion [2] [3]. In this phenomenon changes the waveform of the wave base. Harmonics are symptom formation of waves at different frequencies. It is called frequency harmonics arising from the original waveform, while integer multiplier fundamental frequency is called harmonics sequence number. Is an example of a comparison of the basic waveform and harmonic wave [4] [5]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.