Abstract

The transient overvoltages associated to the interruption of high direct currents with high current derivative, at the base of the operation of a Quench Protection System for Superconducting Coils, have been studied, with particular reference to the JT-60SA project, which adopt edge technology solutions for current interruption: a Hybrid mechanical-static Circuit Breaker as main circuit breaker in series with a PyroBreaker as backup protection. The paper reports in particular on the analyses of the intervention of the backup circuit breaker in the final circuital conditions, considering the actual power connections that will be implemented on Site. The key elements which influence the peak value of the voltage and the relation existing among the different stray impedances of the circuit are identified, thus giving general guidelines for the design of the layout of the power connections. The specific case of JT-60SA is considered, but general criteria can be derived.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.