Abstract

Background:
 Based on the preliminary test using laboratory tests from three refill drinking water samples in Jemur Wonosari Village, all three were positive for Coliform. Therefore, researchers are interested in researching Analysis of the Microbiological Quality of Refilled Drinking Water at the Refill Drinking Water Depot in Jemur Wonosari Village.
 Objectives:
 Knowing the microbiological quality of refill drinking water produced at the refill drinking water depot in Jemur Wonosari Village.
 Research Methods: 
 This research is a descriptive study with a cross-sectional quantitative approach using primary and secondary data sources. The population in this study were all 13 refill drinking water depots. The research takes the total population. Refillable drinking water samples were tested at the Gayung Sari Regional Health Service Laboratory. Data analysis used descriptive analysis by comparing the results of laboratory tests with Permenkes 492 of 2010.
 Results: 
 The results showed that 13 samples found that 13 samples were positive for Coliform, and 13 samples were negative for Escherichia coli. According to Permenkes No. 429 of 2010, the maximum limit per 100 ml of sample is 0. So the 13 samples of refill drinking water based on microbiological parameters, namely Escherichia coli in refilled drinking water, meet the standard while the Coliform does not meet the standard.
 Conclusion: 
 All refill drinking water depots in Keluraham Jemur Wonosari produce refilled drinking water whose quality does not meet the government's microbiological standards. There is a need for increased supervision and guidance at refill drinking water depots.

Highlights

  • Based on the preliminary test using laboratory tests from three refill drinking water samples in Jemur Wonosari Village, all three were positive for Coliform

  • Results: The results showed that 13 samples found that 13 samples were positive for Coliform, and 13 samples were negative for Escherichia coli

  • Uji Kualitas Air Minum Isi Ulang di Kecamatan Sukolilo Surabaya Ditinjau dari Perilaku dan Pemeliharaan Alat

Read more

Summary

Air minum lainnya

Saat ini jarang sekali masyarakat yang memasak air untuk diminum. Masyarakat diperkotaan cenderung mengkonsumsi Air. Faktor mikrobiologi memiliki dampak langsung terhadap masyarakat yang meminum air minum isi ulang tidak layak atau belum memenuhi standart, dampak ditimbulkan yaitu penyakit diare. Penelitian mengenai DAMIU menunjukan 4 dari 6 sampel air minum isi ulang telah memenuhi syarat sesuai baku mutu Peraturan Menteri Kesehatan No. 429 Tahun 2010. Sehingga perlu dilakukan analisis air minum isi ulang dengan cara uji laboratorium air minum isi ulang yang disesuaikan dengan standart air minum layak di konsumsi dalam Peraturan Menteri Kesehatan No 429 Tahun 2010, serta faktor mikrobiologi pada air minum memiliki efek langsung bagi tubuh jika dikonsumsi oleh manusia. Kandungan bakteri Escherichia Coli pada air minum isi ulang di Kelurahan Jemur Wonosari. Kelurahan Jemur Wonosari seperti terlihat pada tabel sebagai berikut: Tabel 3 Hasil uji laboratorium air minum isi ulang parameter bakteri Escherichia coli di wilayah Jemur

Tidak sampel memenuhi syarat
Kandungan Bakteri Coliform pada
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call