Abstract

The use of low-cost working electrodes is of great importance for the development of sensor industrialization. Acupuncture needles electrode (ANE) was selected as working microelectrode, a sensor was designed based on poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT: PSS) and chitosan (CS) modified covalent organic frameworks (COFs) (CS/COFs) for detection of cadmium (Cd(II)). First, a mixture of PEDOT and PSS was electrodeposited on the surface of the acupuncture needles to synthesize a PEDOT: PSS as conductive polymeric film to support the electron transfer capability and enhance the conductive efficiency of the sensor. Then, CS/COFs was self-assembled and attached to the PEDOT: PSS/ANE surface by π-π stacking intermolecular interaction forces and the viscosity of CS, thus increasing the specific surface area of the electrode. Differential pulse anodic stripping voltammetry (DPASV) was used as the electrochemical method for detection of Cd(II). And the results indicated that the CS/COFs/PEDOT: PSS/ANE was linearly responsive in the range of 400 μg/L to 2400 μg/L, and the LOD was 13.8 ng/L for Cd(II). The constructed sensor also showed great selectivity, reproducibility, and stability. Additionally, the sensor demonstrated outstanding recovery in the detection of Cd(II) in real sample scallops. This sensing construction method based on acupuncture needles as working electrodes is of great significance to the development of sensor industrialization and aquatic product safety detection.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call