Abstract
In order to reduce the vast total harmonic distortion (THD) caused by hysteresis loop space vector control strategy in three-phase Voltage Source Rectifier (VSR), an optimized strategy based on fuzzy rules is proposed in the paper. In the new strategy, a current error vector threshold value was pre-set. When the actual current error value is less than the threshold, the hysteresis loop space vector control strategy will be adopted to reduce the switching frequency and loss. However, when the current error value is larger than the threshold, the optimized hysteresis loop control strategy based on fuzzy rules will be adopted to achieve the fast current tracking. Based on the new strategy, the simulation model has been established and simulated by matlab/simulink. And the results show that the optimized control strategy not only ensures the fast dynamic response with low switching frequency, but also reduces the current THD significantly. Finally, the feasibility and the superiority of the optimized strategy based on fuzzy rules have been further verified under a 1kW experiment system.
Published Version
Talk to us