Abstract

To assess the relative bioavailability and pharmacokinetic properties of two formulations (test and reference) of Lafutidine 10 mg. The study was performed as an open label, randomized, two-way, two-period, two-treatment, single dose cross-over bioequivalence study, under non-fed condition to compare the pharmacokinetic profiles of the lafutidine formulation manufactured by Emcure Pharmaceuticals Ltd., India using an indigenously developed active pharmaceutical ingredient (API) and the commercially available Stogra(®) formulation, of UCB Japan Co., Ltd., Japan. The two treatments were separated by a wash-out period of 5 d. After an overnight fasting period of 10 h, the subjects were administered either the test or the reference medication as per the randomization schedule. Blood samples were collected at intervals up to 24 h, as per the approved protocol. Concentrations of lafutidine in plasma were analyzed by a validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, and a non-compartmental model was used for pharmacokinetic analysis. The pharmacokinetic parameters were subjected to a 4-way ANOVA accounting for sequence, subjects, period and treatment. Statistical significance was evaluated at 95% confidence level (P ≥ 0.05). The mean (± SD) values of the pharmacokinetic parameters (test vs reference) were C(max) (265.15 ± 49.84 ng/mL vs 246.79 ± 29.30 ng/mL, P < 0.05), Area under the curve (AUC)((0-t)) (1033.13 ± 298.74 ng.h/mL vs 952.93 ± 244.07 ng.h/mL, P < 0.05), AUC((0-∞)) (1047.61 ± 301.22 ng.h/mL vs 964.21 ± 246.45 ng.h/mL, P < 0.05), and t(½)(1.92 ± 0.94 h vs 2.05 ± 1.01 h, P < 0.05). The 90% confidence intervals (CI) for the test/reference ratio of mean C(max), AUC((0-t)), and AUC((0-∞)) were within the acceptable range of 80.00 to 125.00. The mean times (± SD) to attain maximal plasma concentration (t(max)) of lafutidine were 0.95 ± 0.24 h vs 1.01 ± 0.29 h (P < 0.05) for the test and the reference formulations respectively. Both the formulations were well tolerated. In summary, this study has demonstrated the bioequivalence of the two formulations of lafutidine 10 mg. Hence it can be concluded that the two formulations can be used interchangeably in clinical settings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.