Abstract

Vibration signals are usually used to monitor friction fault between stator and rotor of steam turbine in fossil-fuel power plant indirectly, and the effect is not ideal due to the limitation of vibration meter and heavy mass of rotor. The reason why vibration signals can not monitor friction fault between stator and rotor of steam turbine is analyzed in this paper in theory. A method of monitoring friction fault between stator and rotor of steam turbine based on acoustic emission (AE) technology is supposed. An online monitoring system of friction fault for steam turbine is designed. It is shown that the monitoring system can measure friction fault between stator and rotor of steam turbine effectively and accurately and improve the reliability of steam turbine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.