Abstract

Objective Out-of-hospital clinical experience with noninvasive bilevel positive airway pressure (BiPAP) ventilation is extremely limited compared to inhospital management. The aims of this study were to assess the feasibility of out-of-hospital BiPAP ventilation in patients with acute respiratory distress of various origins, and to look for specific factors associated with failure of this respiratory support. Methods This 2-year prospective observational study assessed the failure rate of out-of-hospital BiPAP ventilation, the difficulties encountered, and factors predictive of failure by multivariate analysis. Results Overall, 138 patients were treated by out-of-hospital BiPAP for congestive heart failure (56%), chronic obstructive pulmonary disease exacerbation (28%), and acute respiratory failure (16%). Failure rate was 26% (35/138; 95% confidence interval, 18%-33%) (11 before and 24 after reaching hospital). Independent risk factors were the cause of respiratory distress (chronic obstructive pulmonary disease exacerbation; acute respiratory failure) and an audible air leakage. Conclusions The failure rate of BiPAP initiated out-of-hospital was no different from previous reports for inhospital failure rates. Failure was attributable to similar causes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call