Abstract
Feeder pipes that connect the inlet and outlet headers with the in-reactor fuel channels in CANDU nuclear power plants are considered as safety Class 1 piping items. Therefore, fatigue of feeder pipes should be assessed at design stage in order to verify structural integrity during design lifetime. In accordance with the fatigue assessment result, cumulative usage factors of some feeder pipes have significant values. The feeder pipes made of SA-106 Grade B carbon steel have some elbows and bends. An active degradation mechanism for the carbon steel outlet feeder piping is local wall thinning due to flow-accelerated corrosion. Inspection results from plants and metallurgical examinations of removed feeders indicated the presence of localized thinning. This local wall thinning can cause increase of peak stress due to stress concentration by notch effect. The increase of peak stress results in increase of cumulative usage factor. However, present fatigue assessment doesn’t consider the stress concentration due to local wall thinning. Therefore, it is necessary to assess the effect of local wall thinning on stress concentration. This study investigates the effect of local wall thinning geometry on stress concentration by performing finite element elastic stress analysis.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have