Abstract

The results of computational hydrodynamic simulation of the flow of a working medium in the flow path of the feedwater control assembly used in power units of nuclear power plants (NPPs) equipped with the reactors of the RBMK-1000 type are presented It was established that the rate of control valve opening has an influence on the position of the areas of the intense local erosion-corrosion thinning of metal of the diffuser section downstream of the valve.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.