Abstract

In the radiant cooler, where the hot gas from the pulverized coal gasifier or combustor is cooled to generate steam, the wall heat-transfer coefficient varies due to ash deposition. In the present work, we investigate an inverse radiation problem of estimating the heat-transfer coefficient from temperature measurement in the radiant cooler. The inverse radiation problem is solved through the minimization of a performance function, which is expressed by the sum of square residuals between calculated and observed temperature, utilizing the conjugate gradient method. The gradient of the performance function is evaluated by means of the improved adjoint variable method, which resolves the difficulty associated with the singularity of the adjoint equation through its inherent regularization property. The effects of the number of measurement points and measurement noise on the accuracy of estimation are also investigated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.