Abstract

An original non-invasive methodology of the fuel cell diagnosis is proposed to identify different positions of the faults in Proton Exchange Membrane Fuel Cell (PEMFC) stacks from external magnetic field measurements. The approach is based on computing the external magnetic field difference between normal and faulty PEMFC operating conditions. To evaluate the external magnetic field distribution, in this paper, we propose an improved design of the magnetic field analyzer. This analyzer amplifies the magnetic field around the cell to perform an accurate detection of the fault position. Moreover, the main contribution of this work is represented by conceiving and implementing a 3D multi-physical current distribution emulator of a proton exchange membrane fuel cell. The new concept of a proton exchange membrane fuel cell emulator has been specially designed to emulate the magnetic field of a real fuel cell stack. This emulator concept is also beneficial for a new model of the fuel cell, which implies a multi-physical coupling between electrochemical electric conduction and the generated magnetic field. Finally, finally, the numerical model and the emulator have been involved in the realization of numerical simulations and experimental analysis to prove the ability of the system to detect and localize 3D faults.