Abstract

The data weighted averaging (DWA) algorithm used in multibit sigma-delta modulators (SDM) is troubled by baseband tones resulting from component mismatch of the SDM's internal multi-bit digital-to-analog converter (DAC). In this paper, we analyze DAC baseband tones and find them closely correlated to the number of unit elements used in the DAC. An improved technique is proposed for shifting the DAC tones away from the baseband without adding dither. For third-order sigma-delta modulators with an oversampling ratio (OSR) of 64 and either a nine-level or eight-level internal DAC with 0.5%-2% random component mismatches, simulation reveals that the DWA algorithm with the proposed technique can achieve nearly perfect first-order DAC noise shaping in the baseband and, on the average, 12 dB improved signal-to-(noise and distortion) ratio and 20 dB improved in-band distortion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.