Abstract

A time-saving method was developed to label red blood cells in vitro with 99mTc while avoiding centrifugation. After tin incubation, extracellular tin was oxidized by sodium hypochlorite, and EDTA was added for stabilizing the complex prior to 99mTc incubation. Labeling yields were 95%, and in vivo decay showed a high stability with a mean biologic half-life of eleven hours. The first-passage radionuclide technique for determination of cardiac output using the above-mentioned tracer was evaluated by using the left ventricle as area-of-interest with individual background correction after complete mixing of the tracer. This technique showed a high level of agreement with invasive methods. By combining this method for measurement of the forward stroke volume with the multigated equilibrium principle for determination of the total left ventricular stroke volume using similar background corrections, an exact evaluation of regurgitation fractions was obtained. In patients with aortic and mitral valve disease the noninvasive radionuclide technique gave similar but probably more accurate results as compared with contrast aortography and ventriculography. The radionuclide technique may be suitable for monitoring and selecting patients for surgical treatment.