Abstract

The hysteresis current controllers (HCC) for grid-connected inverter (GCI) system is a well-known controller for its robustness, fast reference tracking, better dynamics, and easier implementation compared to other controllers. This article proposes a modified double-band HCC (MDBHCC) for single-phase GCI system with LCL -filter. The proposed algorithm implements an unipolar symmetrical pulse width modulation (PWM) strategy for reducing inverter switching losses through a sequential logic, with an adaptive clock. It improves the variation in switching frequency and limits the maximum switching frequency of HCC while enhancing the total harmonic distortion (THD) of the injected current into the grid. In order to alleviate power quality problems, two such MDBHCC schemes, i.e., MDBHCC1 and MDBHCC2, are implemented. Where MDBHCC2 operates at the higher switching frequency with lesser % THD and MDBHCC1 operates at lower switching frequency. Simulation and experimental results are presented with a significant decrease in switching frequency and an improvement in grid current harmonics at both steady-state and dynamic conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.