Abstract

A vacuum apparatus to measure thermal contact conductance (TCC) was introduced. A TCC test method and procedure was presented. By monitoring the temperature distribution on the test specimen, the heat flux and temperature drop of the contact interface were calculated, and then the TCC was obtained. The experimental research was conducted with pressed pairs SS316L/CuCrZr contacts in a range of 100∼300°C and 1∼10MP. The experimental data analysis results show that the TCC increases with the increase of contact temperature and the TCC also grows with the growth of contact pressure. The TCC appears as a linear relationship with the change trend of pressure at a given temperature. By uncertainty analysis, the measurement error of TCC decreases with the increase of contact pressure at a given temperature. And the variation rate of measurement error increases with the rise in contact temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.