Abstract

In order to reduce power consumption and conveying velocity, a new pneumatic conveying system where soft fins are horizontally mounted on the center plane of pipe in the front of inlet is proposed in this paper. The experimental study focuses on the effect of the different fin's lengths on the horizontal pneumatic conveying system in terms of frequency characteristics of fin's oscillation, pressure drop, conveying velocity, power consumption and particle flow pattern. Comparing with the conventional pneumatic conveying, the pressure drop, minimum and critical velocities and power consumption can be reduced by using soft fins in lower air velocity range. The effective of fin is quite evident with increasing the length of fin. The maximum reduction rates of the minimum velocity and power consumption by using soft fins are about 14.8% and 25.5%, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.