Abstract

Many actions, such as accidental or malicious explosions, may impose high loading rates to structural frames. To enhance the knowledge of the behaviour of joints subjected to severe impulsive loading, a double-sided beam-to-column joint configuration was tested at quasi-static and dynamic loading rates. The test specimens consisted of H-section beams and columns, extended end-plates, and high-strength bolts. In both the quasi-static and dynamic tests, the fracture modes were bolt failure in combination with plastic deformation of the end-plates. However, it was observed that the joints absorbed considerably more energy before failure in the dynamic tests than in the quasi-static tests, partly due to changes in the deformation modes. Also, the ductility of the joints seemed to increase for higher loading rates. These results suggest that the tested joints behave in a preferable manner under extreme impulsive loads.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.