Abstract
The experimental investigation were conducted in order to study the dynamic strength of the mechanically fastened composite joints, involving interference-fit joints with blind bolt and sliding-fit joints with high lock bolt. The joint type of the specimens researched was single-bolt, double-lap, which was a standard test configuration in ASTM for composite joints. Experimental results showed that the fatigue performance of the blind bolted joint was better than that of the high-locking bolted joint. The fatigue life of the blind bolted joints was 10-100 times higher than that of the high-locking bolted joint under the same cyclic stress, and the limit fatigue strength of the blind bolted joints was over 50MPa higher than hat of the high-locking bolted joints.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: DEStech Transactions on Engineering and Technology Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.