Abstract
Experiments were conducted in a cold model circulating fluidized bed having riser cross-sectional area of 100 mm × 100 mm, height of 4.8 m, bed temperature of 75 °C and superficial velocity of 8 m s −1. Local sand having average diameter of 231 μm was used as bed material. The experiments were conducted for three tube configurations: membrane tube, membrane tube with a longitudinal fin at the tube crest and membrane tube with two longitudinal fins at 45° on both sides of the tube crest. The results show that membrane tubes with one and two longitudinal fins have higher heat transfer than membrane tubes and the heat is mainly transferred in the combination portion of tube and membrane fins. In addition, the membrane tube has the highest heat transfer coefficient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.