Abstract

Abstract : Measured radiation patterns of a plasma-covered antenna are compared with an approximate leaky wave analysis due to Oliner and Tamir. The results clearly show a shift in the optics ''critical angle'' and the appearance of several side lobes are predicted by theory. The plasma is produced in a He - Xe admixture at 0.4 torr by a capacitively-coupled 10-Mcps cw source and contained in a rectangular pyrex vessel of interior dimensions 8 in. by 4 in. by 5 in. Electron densities in excess of 5 x 10 to the 11th power per cc are measured by a standard microwave interferometer by manually balancing a bridge or automatically by displaying a set of interference ''fringes'' after a pattern is recorded. (Author)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.