Abstract

This study investigates the fracture behavior of thick adhesive joints manufactured with composite adherends and bonded with an epoxy-based structural adhesive common to the wind turbine industry. For that purpose, double cantilever beam specimens with an adhesive thickness of approximately 10 mm and different pre-crack lengths are manufactured and tested under mode I loading. Analytical approaches are compared to assess the energy release rate, including the simple beam theory, modified beam theory, compliance calibration method, and beam on an elastic and elastic-plastic foundation. In order to evaluate the applicability of the analytical approaches, an in-situ measurement method based on Digital Image Correlation is also employed to determine the energy release rate of the thick adhesive joints. The crack propagation angle is determined theoretically using the second-order crack kinking theory. A good correlation is observed between the theoretical predictions and experimental results. Furthermore, it is demonstrated that due to the T-stress, the crack tends to deviate from the middle of the joint and propagate towards the interface. By comparing different data reduction methods to evaluate the energy release rate of thick adhesive joints, recommendations for their fracture analysis are made, pinpointing the beam on an elastic and elastic-plastic foundation as the most suitable model.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call