Concentrated static and step loading were applied to circular arches with geometric parameters 7 < γ < 20. The static equilibrium path and the dynamic response at the loading position were recorded. Dynamic buckling is distinct. Supercritical and subcritical response were separated by 0.5 percent of the total load. The sensitivity of the arch to off set loading was studied. The effect was pronounced in the static tests but moderate in the dynamic case. An energy approach was used to determine the lower, and upper bound for the critical step load. The lower bound agrees well with the experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.