Abstract

<p>This paper presents a computer model of an electrical rotating machine with high-coercivity permanent magnets and research of various short-circuit types in the electrical rotating machine with high-coercivity permanent magnets, including turn-to-turn short circuit. Diagnostic criteria of short circuits are revealed. There are the electromagnetic moment and the magnetic flux density in the stator core back. With comparison the experiment and computer modeling results, it was found that the created computer model is highly accurate and completely repeats the experiment results. The numerical discrepancy between the experimental data and the simulation data is below 5%. The obtained results can be used in practice in the design of the electrical rotating machine with high-coercivity permanent magnets.</p>

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.