Abstract
Abstract Modified laboratory scale activated sludge units were designed and constructed specifically for excess biological phosphorus removal. Once operational several modifications were executed to enhance the removal of phosphorus, these included the improvement of anaerobic conditions; augmentations with acetate and Acinetobacter /Aeromdnas species; increases in sludge age and temperature. The major factor found to influence phosphorus removal was temperature, a 1°C increase resulted in a 2.6% increase in phosphorus removal in the 12–25°C temperature range. During periods of high removal experiments were undertaken to identify the mechanism involved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.