This study proposed simply design procedure of a single degree of freedom (SDOF) structure equipped with friction dampers. General method is suggested in order to reduce the structural seismic response by using friction dampers. The analysis model was transformed into an equivalent mass-spring-dashpot system by approximating nonlinear friction damping force with equivalent viscous damping force. A closed form solution for dynamic amplification factor (DAF) for steady-state response was derived by the energy balance equation. The equivalent damping ratio was defined by using DAF at natural frequency. The transfer function between input harmonic excitation and output structural response was obtained from the DAF, and the response reduction factor of the root mean square (RMS) for displacements without and with friction dampers was analytically determined. Using the proposed procedure the friction force required for satisfying given target response reduction factor was obtained. Mean response reduction factors matched well with the target values based on the dynamic analysis results. It is concluded that the proposed method is quite simple for the design of friction dampers to reduce seismic response of the structure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.