Abstract

The automatic real-time detection of spike-wave discharges (SWDs), the electroencephalographic hallmark of absence seizures, would provide a complementary tool for rapid interference with electrical deep brain stimulation in both patients and animal models. This paper describes a real-time detection algorithm for SWDs based on continuous wavelet analyses in rodents. It has been implemented in a commercially available data acquisition system and its performance experimentally verified. ECoG recordings lasting 5–8 h from rats ( n = 8) of the WAG/Rij strain were analyzed using the real-time SWD detection system. The results indicate that the algorithm is able to detect SWDs within 1 s with 100% sensitivity and with a precision of 96.6% for the number of SWDs. Similar results are achieved for 24-h ECoG recordings of two rats. The dependence of accuracy and speed of detection on program settings and attributes of ECoG are discussed. It is concluded that the wavelet based real-time detecting algorithm is well suited for automatic, real-time detection of SWDs in rodents.