Abstract
BackgroundExtracting cardiorespiratory signals from non-invasive and non-contacting sensor arrangements, i.e. magnetic induction sensors, is a challenging task. The respiratory and cardiac signals are mixed on top of a large and time-varying offset and are likely to be disturbed by measurement noise. Basic filtering techniques fail to extract relevant information for monitoring purposes.MethodsWe present a real-time filtering system based on an adaptive Kalman filter approach that separates signal offsets, respiratory and heart signals from three different sensor channels. It continuously estimates respiration and heart rates, which are fed back into the system model to enhance performance. Sensor and system noise covariance matrices are automatically adapted to the aimed application, thus improving the signal separation capabilities. We apply the filtering to two different subjects with different heart rates and sensor properties and compare the results to the non-adaptive version of the same Kalman filter. Also, the performance, depending on the initialization of the filters, is analyzed using three different configurations ranging from best to worst case.ResultsExtracted data are compared with reference heart rates derived from a standard pulse-photoplethysmographic sensor and respiration rates from a flowmeter. In the worst case for one of the subjects the adaptive filter obtains mean errors (standard deviations) of -0.2 min −1 (0.3 min −1) and -0.7 bpm (1.7 bpm) (compared to -0.2 min −1 (0.4 min −1) and 42.0 bpm (6.1 bpm) for the non-adaptive filter) for respiration and heart rate, respectively. In bad conditions the heart rate is only correctly measurable when the Kalman matrices are adapted to the target sensor signals. Also, the reduced mean error between the extracted offset and the raw sensor signal shows that adapting the Kalman filter continuously improves the ability to separate the desired signals from the raw sensor data. The average total computational time needed for the Kalman filters is under 25% of the total signal length rendering it possible to perform the filtering in real-time.ConclusionsIt is possible to measure in real-time heart and breathing rates using an adaptive Kalman filter approach. Adapting the Kalman filter matrices improves the estimation results and makes the filter universally deployable when measuring cardiorespiratory signals.
Highlights
Extracting cardiorespiratory signals from non-invasive and non-contacting sensor arrangements, i.e. magnetic induction sensors, is a challenging task
Note that in the first 22.5 s, frequency estimation neither for the respiration rate nor for the heart rate is computed
The above analysis shows that estimations of respiration and heart rate based on the implemented adaptive Kalman filter perform very well in a real-time acquisition scenario employing contactless sensors measuring cardiorespiratory signals
Summary
Extracting cardiorespiratory signals from non-invasive and non-contacting sensor arrangements, i.e. magnetic induction sensors, is a challenging task. Basic filtering techniques fail to extract relevant information for monitoring purposes The increase in both life quality expectancy and quality of life, together with improvements in medical support, has led to an increase in the mean age of the population in developed lands. The goal of personal health care is to relieve clinicians and the clinical infrastructure by means of technical improvements, but without reduction in diagnostic and rehabilitation performance, e.g. with telemonitoring at home [2]. This implies that new technology needs to be integrated into daily activity which, compared with a well-defined clinical environment, poses considerable challenges in terms of signal acquisition and processing. One algorithmic approach is the use of the Kalman filtering technique
Published Version (Free)