Abstract
A novel catechol biosensor was described based on the immobilization of polyphenol oxidase (PPO) into polyaniline (PANI), which was easily constructed by direct electropolymerization of aniline in a solution containing ionic liquid, 1-ethyl-3-methylimidazolium ethyl sulfate (EMIES). The developed biosensor for the detection of catechol has a linear range of 1.25–150μmoldm−3. The maximum response current (Imax) and the Michaelis–Menten constant (k′m) are 0.62μA and 146μmoldm−3, respectively. The activation energy (Ea) of the PPO catalytic reaction is 31.1kJmol−1 in the B–R buffer. The biosensor shows good reproducibility (a relative standard deviation of 3.1% was obtained) and remarkable long-term stability (it retains 75% of the original activity after four months). The effects of potential and pH on the response current of the biosensor are also described.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.