Conducted emission tests are always performed by the use of LISNs in laboratories in accordance with CISPR22, CISPR11 and other similar standards. However, it is not always possible to use LISNs because of some limitations. If the EUT (Equipment Under Test) has large dimensions or high currents, it is not, for most of the time, possible to send it to an EMC laboratory or to use LISNs during the test. As a consequence, usage or development of alternative conducted emission test methods is inevitable in industry. In this paper, we made conducted measurements on actual EUTs in alternative environments whose impedances are different from the standard LISN impedance and continued to establish the fundamentals of alternative conducted emission tests based on the impedance measurements of the EUT, supply and used cables. We also established the correlation, on the basis of impedance measurements, between these alternative conducted emission test method and the reference conducted emission test method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.