Abstract

The chemical selectivity of the target and ion-source production system is an asset for radioactive ion-beam (RIB) facilities equipped with mass separators. Ionization via laser induced multiple resonant steps has such selectivity. However, the selectivity of the ISOLDE resonant ionization laser ion-source (RILIS), where ionization takes place within high temperature refractory metal cavities, suffers from unwanted surface ionization of low ionization potential alkalis. In order to reduce this type of isobaric contaminant, surface ionization within the target vessel was used. On-line measurements of the efficiency of this method is reported, suppression factors of alkalis up to an order of magnitude were measured as a function of their ionization potential. The time distribution of the ion-bunches produced with the RILIS was measured for a variety of elements and high temperature cavity materials. While all ions are produced within a few nanoseconds, the ion-bunch sometimes spreads over more than 100 μs. This demonstrates that ions are confined within high temperature metallic cavities. It is the internal electrical field of these cavities that causes the ions to drifts to the extraction region and defines the dwell time of the ions in the cavity. Beam optics calculations were carried out to simulate the pulse shape of a RILIS ion-bunch and are compared to the actual measurements.

Highlights

  • The time distribution of the ion bunches produced with the Resonant Ionization Laser Ion-Source (RILIS) was measured for a variety of elements and high temperature cavity materials

  • While all ions are produced within a few nanoseconds, the ion bunch sometimes spreads over more than 100 μs. This demonstrates that ions are confined within high temperature metallic cavities

  • The chemical selectivity of the target and ion-source production system is an asset for Radioactive Ion-Beam (RIB) facilities equipped with mass separators

Read more

Summary

Introduction

In order to reduce this type of isobaric contaminant, surface ionization within the target vessel was used. The selectivity of the ISOLDE Resonant Ionization Laser Ion-Source (RILIS), where ionization takes place within high temperature refractory metal cavities, suffers from unwanted surface ionization of low ionization potential alkalis.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.