Abstract

Alignment sensing is often required in precision interferometry applications such as Advanced LIGO in order to achieve the optimum performance. Currently favored sensing schemes rely on the use of two separate radio-frequency (RF) quadrant photodetectors and Gouy phase telescopes to determine the alignment of a beam relative to an optical cavity axis. In this paper, we demonstrate an alternative sensing scheme that has potential advantages over the current standard schemes. We show that by using electro-optic beam deflectors to impose RF jitter sidebands on a beam, it is possible to extract full alignment signals for two in-line optical cavities from just one single-element photodetector in reflection of each cavity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.