Abstract
The distribution of gas and liquid phases was studied experimentally in air-water two-phase flow flowing through a pipe junction with the branching angle of 90°and the area ratio of unity. The main of the junction was set up vertically and upward air-water bubbly and slug flows were arranged in the main upstream section. As the result, the local void fraction distribution in the main upstream section is almost axisymmetry. More air in the main upstream section flows into the lateral than that in the main downstream section. Therefore, nonsymmetry of the local void fraction distribution in the lateral is more remarkable than that in the main downstream section.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.