Abstract

In the absence of End of Service Life Indicator (ESLI), a cartridge change schedule should be established for ensuring that cartridges are changed before their end of service life. Factors effecting service life of cartridges were evaluated, including the amount of atmospheric contamination with aromatic hydrocarbon vapors in the workplace, temperature, and relative humidity of the air. A new change schedule was established based on comparing the results of air monitoring and workplace conditions, laboratory experiment, and the NIOSH MultiVapor software. Spray painters were being exposed to aromatic hydrocarbons in a range exceeding occupational exposure limits. The cartridge change schedule was not effective and could no longer provide adequate protection against organic contaminants for sprayers. Change schedules for respirator cartridges should be reduced from 16–24 hours to 4 hours. NIOSH’s service life software program could be applied to developing cartridge change schedules.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.