Abstract
ABSTRACTA passive visual end of service life indicator (ESLI) for certain organic vapors has been attached to the inside wall of an organic vapor respirator cartridge. The opposite side of the ESLI touches activated carbon inside the cartridge. During use, organic vapors moving through the cartridge adsorb into both the carbon and the ESLI. The cartridge body is clear so that when vapor concentrations meet a certain threshold, the user may observe the progressive development of an indicator bar down the side of the ESLI. The cartridge is deemed ready to change when any part of the indicator bar touches a marked end line. The performance of the ESLI was observed when the cartridge was tested against a variety of organic vapors, exposure concentrations above the minimum indication level, humidities, temperatures, flow rates, and mixtures. In all cases, the ESLI indicated end of service life with more than 10% cartridge service life remaining (which is a NIOSH test criteria). The results were also compared to mathematical predictions of cartridge service life.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.