Abstract

The ability of a water-spray to entrain large quantities of air offers the possibility of assisting the dispersion of ground-hugging heavy-gas plumes, thereby reducing the hazard. An analytical study has been carried out of the response of a heavy-gas plume to the action of a series of water sprays distributed across the direction of drift of the plume. Such a distribution is referred to as water-spray barrier and its effect is represented in the analytical model as a line source of air. The concentration distribution in the plume is calculated by means of a ‘box’ model for heavy-gas dispersion. The infuence of the following factors is investigated: (1) the distance from the source of gas to the barrier; (2) the strength of the line source representing the barrier; and (3) the way in which the action of the barrier changes the geometry of the plume. The results obtained are relevant to the design of practical installations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.