Abstract
Tunnel Oxide Passivating Contacts (TOPcon) battery in the photovoltaic industry generates high ammonium wastewater during the production process, the adaptability of using the anaerobic ammonia oxidation (Anammox) process for photovoltaic wastewater (PVW) treatment is a research hotspot. Based on the analysis of photovoltaic wastewater quality, the effectiveness of nitrogen removal, sludge characteristics and microbial communities were examined. The results showed that when the influent NH4+-N concentration of PVW was lower than 150 mg·L−1, the nitrogen removal efficiency (NRE) was almost 100 %. In addition, the NRE decreased from 74 % sharply to 20 % when the NH4+-N concentration was increased from 175 mg·L−1 to 200 mg·L−1. The extracellular polymeric substances (EPS) content increased with elevated ammonium concentration in the influent, indicating that microorganisms secreted more EPS to resist elevated nitrogen loading. The main functional populations were Candidatus Kuenenia (0–24 %). The influent ammonium concentration is recommended to be < 200 mg·L−1.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.