Abstract

The precise measurement of very low levels of factor IX activity (FIX:C < 1IU/dL) is essential for understanding clinical severity and risk of inhibitor development in patients with severe hemophilia B (Pw-SHB). However, such measurement sensitivity has not yet been achieved. We aimed to establish a measurement method using clot waveform analysis (CWA). Residual FIX:C by adding anti-FIX monoclonal antibody, FIX:C by adding recombinant (r)FIX to the commercial Pw-SHB plasmas, and FIX:C in our Pw-SHB were determined by CS-2000i™/CS-2400™, followed by analysis of CWA parameters. The presence of anti-FIX antibody in the commercial Pw-SHB plasmas significantly decreased coagulation potential compared to its absence. The addition of rFIX to these innate plasma samples produced significant changes in three parameters upon adding FIX:C at 0.1-1IU/dL, supporting the presence of trace FIX:C in Pw-SHB. Therefore, appropriate FIX-depleted plasma containing minimum residual FIX:C was chosen from reference curves of FIX:C (0.01-1IU/dL). Among patients with untreated Pw-SHB, two had FIX:C 0.6-0.7IU/dL and two had lower than detectable levels using FIX-depleted plasma. One of the latter had detectable trough levels post-rFIX administration. In conclusion, CWA enabled measurement of very low levels of FIX:C using appropriate FIX-deficient plasma.