Abstract

BackgroundAssessing T-wave symmetry in addition to QT subintervals measurements can provide novel independent data about ventricular repolarization abnormalities linked with arrhythmogenesis. However, the causes of the changes of T-wave symmetry are not completely understood. In silico studies showed that the more symmetrical T-waves were associated with shorter action potential duration (APD) and larger dispersion of ventricular repolarization (DOR). The aim of present simulation was to study the association between T-wave symmetry and action potential (AP) shape. MethodsECGs were simulated using a cellular automata model shaped as a ventricular wall segment, and two biophysically-detailed models of ventricular AP – the rabbit and the human. The symmetry ratio (SR) was calculated as a T-wave onset-peak to peak-end area ratio. The individual and combined effects of APD, DOR and AP shape on SR were simulated. To study the effect of AP shape, different APs from triangulated to rectangular were simulated. ResultsThe simulations showed that AP shape along with APD and DOR contributes much to T-wave symmetry. APs with a flat phase 3 (triangulated) produced asymmetrical T-waves (SR ≥ 1.5) in all simulations, except the shortest APD range. APs with a rapid phase 3 (rectangular) were associated with more symmetrical T-waves (SR ≤ =1) both at the short and the long APDs. ConclusionSR marker in combination with the standard ECG parameters (QT interval, Tpeak-Tend interval) may be useful to identify the proarrhythmic triangulated AP shape.