Abstract
Acetabular exposure for direct anterior (DA) total hip arthroplasty (THA) can be performed using hands-free, self-retaining retractors. No current study quantitatively compares this self-retaining technique with the traditional manual technique. In 65 consecutive DA THA hips, two "best-view" digital photographs were taken of the exposure-one using Charnley/self-retaining retractors and one using a traditional three-retractor manual technique. Percent exposure of the polyethylene liner was calculated. Percent acetabular exposure averaged 80.0% using the Charnley/self-retaining technique, compared with 73.1% using the manual technique (P=.0002). A hands-free technique provides superior acetabular exposure compared with the manual technique. Increasing body mass index predicts decreasing exposure with both techniques. [Orthopedics. 2021;44(2):e309-e313.].
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have