Abstract

Objective To conduct a comparative study on the middle-and long-term efficacies of individualized titanium stick angular designs for treating thoracolumbar vertebrate fractures.Methods A total of 96patients were divided into two groups,with 50in the treatment group and 46in the control group.The titanium stick in the treatment group was folded based on the numerical value which had been obtained by measuring and calculating the standard lateral projection of thoracolumbar vertebrate before the operation;the numerical value on sagittal plane was the sum of the average angle of its upper and subtus athletic segment,the angulation of subtus athletic segment and the angle of subtus vertebral body.The titanium stick in the control group was folded based on experience during the operation,with other treatments being the same.The patients were followed-up for at least 6months,with an average of(18±5)months.All the patients received radiography examination pre-and post-operatively.And 42patients received CT examination before and at the last follow-up;another 30patients received MRI examination at last follow-up.Results At the final follow-up,the anterior,posterior vertebral heights were(1.06±0.46)mm and(0.42±0.26)mm for the treatment group and(2.37±0.86)mm(P0.05)and(0.79±0.46)mm for the control group,respectively.The average loss of Cobb angle was(1.57±0.51)°in the treatment group and(2.49±0.89)°in the control group at final follow-up(P0.05).The treatment group had 21cases with fish tail and the control group had 25.The failure rate of internal fixation was 6%in the treatment group and 13%in the control group.The eggshell phenomenon on CT findings was found in 10of the 22patients in the treatment group and in 9of the 20cases in the control group at final follow-up.The neurological status was improved at least by 1Frankel grade in the patients who had preoperative incomplete paraplegia.The scores of Oswestry Disability Questionnaire for the treatment group were:0in 17cases,2in 15cases,4in11cases,6in 2cases,8in 2cases,56in 1case,80in 1case,and 88in 1case;for the control group were 0in 10cases,4in 15cases,6in 11cases,8in 2cases,10in 2cases,18in 2cases,50in 2cases,and 80in 2cases.There were significant differente between the two groups(34%vs 21.74%,P0.05).Conclusion When transpedicle vertebral arch internal fixation system is used for treatment of thoracolumbar vertebrae fractures via posterior approach,individualized titanium stick angular design can accurately regain the physiologic curve of the fixed thoracolumbar segment,reducing operational time,loss of vertebral height correction,failure rate of internal fixation,incidence of backache,and degeneration of adjacent segment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.