Abstract

This letter presents an accurate magnetic coupling coefficient ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$k$ </tex-math></inline-formula> ) model for a through-silicon via (TSV)-based 3-D transformer. The <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$k$ </tex-math></inline-formula> factor can be precisely derived from the self-inductance and mutual inductance, which are calculated by various analytical formulas based on physical geometries. The results of this model correspond well with those of Q3D extractor and high-frequency structural simulator (HFSS), with maximum errors of 3.8% and 4.4%, respectively. An equivalent circuit model of a TSV-based transformer is used for further verification. The S-parameters obtained by the circuit model match well with the measurements.